01 · NOSE SLOPE

Every nose has a different slope

The side of the nose has different slopes vertically and front-to-back.

That is why the same pad angle cannot be used for everyone, and matching the pad to the actual surface makes stable contact easier.

Pad angle is not a one-axis problem. The side of the nose has both vertical and fore-aft slopes, so the pad must be oriented in both directions to reduce the chance that one edge makes contact first.

02 · EDGE PRESSURE

If only an edge touches, pressure becomes concentrated

When only the upper or lower edge of a pad contacts the skin, pressure can concentrate in a small area.

If a deep mark appears mainly at one edge, check angle and contact position before simply changing pad size.

Edge contact can indicate that the load is being carried by a small area. However, the pattern of skin marks also depends on pad size, front weight and skin condition, so do not infer the angle from the mark alone; inspect the actual contact pattern.

03 · STABILITY

Poor angle can reduce stable support

If the pad does not contact the nose stably over a reasonable area, side-to-side movement or slipping can increase.

Slipping also depends on skin condition, pad material and the rest of the fitting, so angle should not be treated as the only cause.

04 · LEFT-RIGHT DIFFERENCE

The two pad angles may need to differ

The left and right slopes of the nose are not always identical.

What matters is broad, stable contact on the wearer, not making both pads look mechanically identical.

The goal is not to make the two pads mirror images of each other. If the two sides of the nose differ in height or slope, the final pad angles may also need to differ. What matters is balanced support and stability on the wearer.

05 · PAD MOVEMENT

Swiveling pads also need their real alignment checked

Some nose pads are designed to move or rotate to a certain degree.

Movement alone does not mean the part is broken, but if a pad repeatedly rotates into an abnormal position or touches only at one edge, inspect the pad box, screw and pad arm.

A swiveling pad may move slightly to follow the nasal surface during wear. If it repeatedly reaches an extreme position, flips, or will not stay aligned, inspect the pad box, screw, pad arm alignment and play rather than blaming the pad surface alone.

SOLUTION GUIDE

Solutions at a glance

Only one end of the pad presses

Check pad angle and nose slope.

One side leaves a much deeper mark

Compare left-right pad angle and pressure.

The glasses still slip despite having nose pads

Check contact area, material and total fitting.

A pad keeps rotating to one side

Inspect the pad structure, screw and pad arm.

GLANOS FITTING CHECK

GLANOS fitting check order

  1. Front
    Check frame alignment.
  2. Nose pads
    Check angle and surface contact.
  3. Width
    Check side support.
  4. Temple bend
    Check rear stability.

CAUTION

Do not repeatedly bend pad arms at home

Pad arms and pad boxes are small, thin components. Repeated incorrect bending can cause fatigue, deformation or breakage.

GLANOS EYEWEAR

There is a reason glasses feel uncomfortable.

CATEGORYNose pads
TOPICNose-pad angle
FRAMEMetal frame
TAGSGLANOS EYEWEAR

nose-pad angle · nose pads · nose marks · metal glasses · slipping glasses · eyewear fitting